experiment EX-VE-TCG-2026-319C
Character-Grid Focus Order and Narrow-Screen Strategy User Tests
EX-VE-TCG-2026-319C: Focus Order and Narrow-Screen Strategy User Tests
Status: not run. On 2026-09-28 the project owner decided to forgo the
participant pilot because participants cannot currently be recruited
(WI-0009 abandoned, recorded under WI-0010). No data exist. The
preregistration and its executable machinery (experiments/ex-ve-tcg-319c,
WI-0008) are kept unchanged, so the studies can run later as specified. This document specifies the studies so that they can be run
and judged against criteria fixed in advance. It must not be cited as
evidence for either hypothesis.
Questions
- HY-VE-TCG-2026-9151. For keyboard-first data entry on a character grid, does focus order equal to row-major field order produce fewer navigation errors than column-major order, for both terminal-experienced and inexperienced users?
- HY-VE-TCG-2026-8750. At 320 CSS px, does a contained, horizontally scrollable grid preserve task accuracy on a position-dependent screen (dense transaction rows) better than reflow, while reflow is better on a label/value screen?
Stimuli
Both studies use the rendered reference screens from Forma's public
contracts (patterns/character-grid-workflow.html: Customer Inquiry,
Account Detail, Transaction History) with synthetic data only. The harness
that presents tasks and logs events is test code outside Forma; Forma
markup is not modified except for the declared conditions below.
Study 1 conditions (HY-VE-TCG-2026-9151)
A two-column entry screen derived from Customer Inquiry: six fields in two columns of three, labels to the left of each field.
| Condition | Focus order |
|---|---|
| R (row-major) | Row by row: left field, then right field, then next row. This is the family rule (CG-6). |
| C (column-major) | Down the left column, then down the right column. |
Condition C violates CG-6 and exists only as an experimental stimulus. It
is built by reordering source, not with positive tabindex, so both
conditions differ only in order. Visual placement is identical.
Study 2 conditions (HY-VE-TCG-2026-8750)
| Screen | Contained (data-ef-narrow="contained") |
Reflow (data-ef-narrow="reflow") |
|---|---|---|
| Transaction History (position-dependent) | grid preserved, viewport scrolls horizontally | runs linearized; the table keeps its own contained scroll |
| Account Detail (label/value) | grid preserved | runs linearized in source order |
Viewport 320 CSS px wide; a second block at 1280 CSS px with 400 % zoom (the SC 1.4.10 equivalent) if the pilot shows the conditions differ.
Participants
Three strata, recruited separately:
- T: at least one year of regular use of a 3270, 5250, or text-mode business application.
- N: no regular terminal use.
- S: screen-reader users (Study 2 only, and Study 1 if recruited), using their own assistive technology.
Sample size is not fixed here because no variance estimate exists. A pilot of six participants per stratum estimates variance; the confirmatory sample per stratum is then set by a power analysis for the primary measure (power 0.8, two-sided α 0.05) and recorded in this document before confirmatory data collection. Pilot data are not pooled with confirmatory data.
Procedure
Within-subject. Condition order is counterbalanced (AB/BA for Study 1; a 2 × 2 Latin square over screen × strategy for Study 2), and data sets are matched but not identical across conditions to limit memory effects.
- Study 1 task: enter a given record into the six fields and submit with Enter. Twelve trials per condition.
- Study 2 tasks: Transaction History: "find the amount and status of the transaction on DATE with DESCRIPTION"; Account Detail: "report the available balance and the overdraft limit". Eight trials per screen and strategy.
Measures
| Study | Primary | Secondary |
|---|---|---|
| 1 | Navigation errors per trial: a value entered in a field other than the one the task instruction was addressing, plus corrective Shift+Tab presses | Completion time; backtracks; subjective workload (NASA-TLX raw) |
| 2 | Task accuracy (correct answer) | Time to answer; horizontal scroll distance; focus stops; subjective preference |
Events are logged by the harness (keydown, focus, input, scroll), with timestamps, as raw JSON per trial. No keystroke content beyond the synthetic task data is stored.
Analysis plan
Mixed-effects models with participant and item as random intercepts: Poisson (or negative binomial if overdispersed) for error counts, logistic for accuracy, and log-time for durations. Fixed effects: condition, stratum, and their interaction. Effects are reported with 95 % confidence intervals, per stratum and pooled.
Falsification criteria (fixed in advance)
- HY-VE-TCG-2026-9151 is falsified if, in the confirmatory sample, column-major order does not produce more navigation errors than row-major order (the interval for the C − R difference includes zero or favors C) in either stratum T or stratum N.
- HY-VE-TCG-2026-8750 is falsified if reflow's accuracy on Transaction History is equal to or better than contained (interval for contained − reflow includes zero or favors reflow), or if reflow is not better than contained on Account Detail.
- A null or adverse result is recorded in the hypothesis registry and in an experiment report. The family rules are not silently changed.
Consequences of outcomes
- 9151 supported: CG-6 stays a rule with user evidence behind A-1. Falsified: the family records that focus order must follow the screen's reading structure, which may be column-major, and Forma's CG-6 becomes a default rather than a rule.
- 8750 supported: the per-screen guidance "contained for position-dependent screens, reflow for label/value screens" becomes evidence-backed. Falsified: the guidance is withdrawn and both strategies are re-examined, especially for stratum S.
Operational definitions (amendment, 2026-09-28, before any data)
These definitions make the measures above computable. They were fixed with
the pilot machinery (experiments/ex-ve-tcg-319c/src/scoring.mjs) before any
participant was recruited, and they change only by a dated amendment made
before the data they would apply to exist.
- Visit. One uninterrupted stay of focus on one element, together with the input events made during it.
- Misentry (Study 1). During a visit to field F the value changed and ended as text of at least two characters that is not a prefix of F's target, but begins with the first two characters of another field's target. A typo inside the right field is not a navigation error. Item generation guarantees that no two targets in a record share their first two characters.
- Corrective Shift+Tab. Every Shift+Tab keydown during a Study 1 trial. The task never requires backward navigation.
- Navigation errors (primary, Study 1). Misentries plus corrective Shift+Tab presses.
- Backtrack. Any focus move to a field earlier in the condition's focus order than the previously focused field, by any means.
- Completion time. From the first keydown to the submit event.
- Correct (primary, Study 2). Every requested part matches the item's answer after removing spaces and thousands separators and ignoring case. A trial without an answer is incorrect.
- Time to answer. From stimulus display to answer submission.
- Scroll distance. The sum of absolute horizontal (and, separately, vertical) position changes over every scroll container and the window.
- Focus stops. Focus events on elements inside the stimulus.
Procedure details the draft left open, fixed the same way:
- The first field has focus when a Study 1 trial starts, as on a terminal. It is first in both orders.
- The Study 1 record card mirrors the screen's 2 × 3 layout, so it favors neither order.
- Study 1 precedes Study 2 for every participant.
- There are no practice trials. Whether the pilot shows a need for them is a pilot question, and adding them is an amendment.
- The Study 2 screen × strategy counterbalancing uses a 4 × 4 Williams design. It balances position and first-order carryover and satisfies the draft's "2 × 2 Latin square over screen × strategy".
- Pilot size stays at six per stratum. Six is not a multiple of four, so Study 2 sequences are used 2, 2, 1, 1 times. Confirmatory sizes are rounded up to a multiple of the sequence count (2 for Study 1, 4 for Study 2).
- Study 2 does not begin until the harness measures the viewport at 320 ± 2 CSS px.
- Stimuli are frozen: Forma commit
30aa31c(CSS, reference workflow markup, and conformance checker) with SHA-256 hashes inexperiments/ex-ve-tcg-319c/protocol/forma-snapshot/manifest.json. Condition C is the only stimulus that breaks a Forma rule (CG-6), and that break is the manipulation.
Open before confirmatory collection: the smallest effect of interest
for each contrast. Until it is set, the power module reports sample sizes
over a grid of candidate effects (protocol/pilot-config.json).
Pilot readiness (2026-09-28)
Ready (WI-0008): stimuli, schedules, item pools, session harness, event logging, scoring, pilot analysis, and power planning. There are 18 unit tests and one browser mechanics check. The mechanics check is a scripted agent, not a participant, and its output can never bear on either hypothesis. It confirms that:
- a row-major typist makes no navigation errors under R and exactly four misentries per trial under C;
- Study 2 answers are scored correctly;
- horizontal scrolling is measured where the grid needs it.
Not ready, and outside what a repository can supply (WI-0009, abandoned on 2026-09-28; see "Decision not to run" below):
- recruitment of strata T, N, and S;
- informed consent;
- the approval route the running organization requires;
- a researcher to run the sessions;
- the smallest-effect-of-interest decision.
Decision not to run (2026-09-28)
The project owner decided to forgo the pilot because participants cannot currently be recruited. The consequences follow the rules above:
- HY-VE-TCG-2026-9151 and HY-VE-TCG-2026-8750 remain untested. Nothing in this repository, including the scripted mechanics check, is evidence for or against either hypothesis.
- CG-6 (focus order equals row-major order) remains a family rule. Its support is EV-VE-TCG-2026-3E25 (3270 practice) and the WCAG focus-order requirement. It has no user evidence for web users.
- The narrow-screen guidance (contained for position-dependent screens, reflow for label/value screens) remains hypothesis-grade guidance. It is not doctrine.
- To run the studies later, capture a new work item. Reuse this specification and its operational definitions unchanged. First confirm that the frozen Forma snapshot is still the intended stimulus, and record the smallest effect of interest.
Ethics and data
Informed consent; participants may stop at any time; synthetic data only; no recording of screens or voices unless separately consented; results stored without direct identifiers. The study needs the approval route the running organization requires; this draft does not constitute approval.
Threats to validity
- Learning effects across conditions (mitigated by counterbalancing and matched data sets).
- The reference screens are a single domain (banking).
- Stratum T participants' expectations may come from one platform (3270 or 5250) and not generalize.
- Browser, font, and assistive-technology versions vary; record them per session.
Required output
An experiment report (EX-VE-TCG-… report) with the pilot variance
estimate and power analysis, the confirmatory results per stratum, raw
event logs, and an update of HY-VE-TCG-2026-9151 and -8750 in